International Plumbing Code 2006 Edition Pdf

Condensate from all cooling coils and evaporators shall be conveyed from the drain pan outlet to an approved place of disposal. Procedure by which an approved testing laboratory provides documentation that a product, material or system conforms to specified requirements. This includes drainage, water supply, vent piping and the necessary fixture supports and any fixtures that are built into the structure. In cases of immediate danger to life or property, such disconnection shall be made immediately without such notice. Types of cleanouts include a removable plug or cap, and a removable fixture or fix- ture trap.

Click here for additional code adoption resources and for sample adoption ordinances. That which is built or constructed or a portion thereof. The board shall modify or reverse the decision of the code official by a concurring vote of three mem- bers. It sets minimum regulations for plumbing systems and components to protect life, health and safety of building occupants and the public. Materials, equipment and devices shall not be reused unless such elements have been reconditioned, tested, placed in good and proper working con- dition and approved.

Item PreviewInternational plumbing code 2006 edition pdfInternational plumbing code 2006 edition pdf

No permit shall be extended more than once. This device shall shut off the equip- ment served in the event that the primary drain becomes restricted. Buried piping shall be supported throughout its entire length. The auxiliary pan drain shall discharge to a conspicuous point of disposal to alert occupants in the event of a stoppage of the primary drain.

Connect With UsICC IPC (2006) International Plumbing Code

The appellant, the appellant's representa- tive, the code official and any person whose interests are affected shall be given an opportunity to be heard. In the absence of recognized and accepted test methods, the way of chuang tzu pdf the code official shall approve the testing procedures. Marginal Markings Solid vertical lines in the margins within the body of the code indicate a technical change from the requirements of the edition. All devices or safeguards required by this code shall be main- tained in compliance with the code edition under which they were installed.

Your account has been marked for password reset. Any pipe that carries wastewater or water-borne wastes in a building drainage system.

An approved connecting device that suitably and properly joins or adjusts pipes and fittings which do not otherwise fit together. Click here for subscription information and archives of past issues.

The provisions of this chapter shall govern the general regulations regarding the installation of plumbing not specific to other chapters. Click here for all open call for committees. The work or installation shall then be resubmitted to the code official for inspection and testing. The overflow drain line shall connect to the drain pan at a higher level than the pri- mary drain connection.

This code shall also regulate nonflam- mable medical gas, inhalation anesthetic, vacuum piping, nonmedical oxygen systems and sanitary and condensate vac- uum collection systems. The over- flow drain shall discharge to a conspicuous point of disposal to alert occupants in the event of a stoppage of the primary drain.

The concrete foun- dation shall be bedded with sand tamped into place so as to provide uniform load-bearing support for the pipe between joints. Where trenches are excavated such that the bottom of the trench forms the bed for the pipe, solid and continuous load-bearing support shall be provided between joints.

Plumbing systems and equipment in structures erected in flood hazard areas shall be constructed in accordance with the requirements of this section and the International Building Code. The number of occupants shall be determined by the International Building Code. This model code also encourages international consistency in the applica- tion of provisions. Piping in a plumbing system shall be installed so as to prevent strains and stresses that exceed the structural strength of the pipe. In any case where plumbing equipment is set up tem- porarily for exhibition purposes.

International Plumbing Code (IPC) Home Page - ICC

Also called vapor, steam, atmo- spheric or exhaust vent. The unobstructed vertical dis- tance through the free atmosphere between the outlet of the waste pipe and the flood level rim of the receptacle into which the waste pipe is discharging.

This comprehensive plumbing code establishes minimum regulations for plumbing systems using prescriptive and perfor- mance-related provisions. Where an emer- gency exists, the code official shall not be required to give a written notice prior to stopping the work. Sheathing or wrapping shall allow for expansion and contrac- tion of piping to prevent any rubbing action. These devices are por- table or are connected to the plumbing system. The principal pipe artery to which branches are con- nected.

The permit holder shall give reasonable advance notice to the code official when the plumbing work is ready for tests. The device shall close by gravity and seal the vent terminal at zero differential pres- sure no flow conditions and under positive internal pressures. The extension of a soil or waste stack above the highest horizontal drain connected to the stack. The fixtures shown are based on one fixture being the minimum required for the number of persons indicated or any fraction of the number of persons indicated. Test methods shall be as specified in this code or by other recognized test standards.

Unless otherwise expressly stated, the following words and terms shall, for the purposes of this code, have the meanings shown in this chapter. The pipe from the water main or other source of potable water supply, or from the meter when the meter is at the public right of way, to the water distribution system of the building served. Conden- sate shall not discharge into a street, alley or other areas so as to cause a nuisance. The edge of the receptacle from which water overflows.

Full text of ICC IPC International Plumbing Code

Applications for the Code Committees have been collected and are being processed. Externally installed devices and devices installed in the drain line shall not be permitted.

International Plumbing Code (IPC) Home Page

Water closet compartments shall not be required in a single-occupant toilet room with a lockable door. Where, in any specific case, different sections of this code specify different materials, methods of construction or other requirements, the most restrictive shall govern. The sample adoption ordinance on page v addresses several key elements of a code adoption ordinance, including the information required for insertion into the code text. Any plumbing regulated by this code that is unsafe or that constitutes a fire or health hazard, insani- tary condition, or is otherwise dangerous to human life is hereby declared unsafe. The pressure in the water supply pipe near the faucet or water outlet while the faucet or water outlet is wide open and flowing.

Braces, blocks, rodding and other suit- able methods as specified by the coupling manufacturer shall be utilized. Upon notice from the code official, work on any plumbing system that is being done contrary to the provisions of this code or in a dangerous or unsafe manner shall immediately cease. It shall be unlawful to make any change in the occupancy of any structure that will subject the structure to any special provision of this code without approval of the code official.

The backfill under and beside the pipe shall be compacted for pipe support. Any heating appliance or equipment that heats potable water and supplies such water to the potable hot water distribution system. Toilet facilities shall be provided for construc- tion workers and such facilities shall be maintained in a sani- tary condition. Only the governmental body that enacts the code into law has such authority.

Bell holes, hub holes and coupling holes shall be provided at points where the pipe is joined. On downflow units and all other coils that have no secondary drain and no means to install an auxiliary drain pan, a water level monitoring device shall be installed inside the primary drain pan. Pipes passing through or under walls shall be protected from breakage. All hearings before the board shall be open to the public.